Solution Type Problem Resolution Sure Solution 2190497.1 : Oracle ZFS Storage Appliance: SNMP community has been reset to 'public' after upgrade
In this Document
Created from <SR 3-13261760063> Applies to:Oracle ZFS Storage Appliance Racked System ZS4-4 - Version All Versions and laterOracle ZFS Storage ZS5-4 - Version All Versions and later Oracle ZFS Storage ZS3-BA - Version All Versions and later Oracle ZFS Storage ZS4-4 - Version All Versions and later Sun ZFS Storage 7420 - Version All Versions and later 7000 Appliance OS (Fishworks) SymptomsSNMP community have been reset to the default public after upgrade to 2013.1.4.0.
ChangesUpgrade from 2013.1.1.7 IDR #1.1 to 2013.1.4.0.
CauseSNMP has been enhanced to support SNMPv3 from Appliance Firmware Release version 2013.1.2.0 onwards. This caused the SNMP community string to reset back to public.
Prior to Appliance Firmware Release version 2013.1.2.0, SNMP configuration is as follow : lbl:> configuration services snmp ls
Properties: <status> = online community = snmp_string network = 10.0.0.0/24 syscontact = admin trapsinks = 127.0.0.1
Upgraded Appliance Firmware Release version to 2013.1.4.2 : lbl:> configuration services snmp ls
Properties: <status> = online version = v1/2c community = public network = 10.0.0.0/24 syscontact = admin username = password = authentication = MD5 privacy = None trapsinks = 127.0.0.1 engineid = 0x80001f8880fae83d7ae174cf5700000000
SolutionCheck/confirm the SNMP configuration after Appliance Firmware Release upgrade.
References<BUG:17443435> - BACKPORT TO AK-2013-REL:SUNBT7147682 APPLIANCE NEEDS TO SUPPORT SNMPV3 FOR SECURAttachments This solution has no attachment |
||||||||||||||||||||
|