![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2190369.1 : Session Border Controller Health Score Falls Below Threshold due to CPU Temperature Alarm
In this Document
Created from <SR 3-13396169071> Applies to:Acme Packet 4500 - Version S-Cz7.3.0 to S-Cz7.3.0 [Release S-Cz7.0]Information in this document applies to any platform. SymptomsSession Border Controller alarm reports that Health Score has fallen below threshold e.g. # display-alarms
Reviewing log files shows the following: log.brokerd:Sep 27 10:16:57.173 [CRITICAL] (0) Temperature Sensor CPU TEMP0 is at 112.125 degrees C, over critical threshold of 100.000 acmelog.2:Sep 27 10:16:54.693 atcpd01@HLBOOR3891N-N-AP-SRRT-01: MINOR Sep 27 10:16:57.173 brokerd@DEVICE: CRITICAL ALARM[00010002] Task[00000013] Temperature Sensor CPU TEMP0 is at 112.125 degrees C, over critical threshold of 100.000
NOTE: The log files are stored in the /opt/logs directory by default
CauseThis is a known issue tracked under Defect 22474551. SolutionThis issue is resolved in SCZ730m2 and later. Information on downloading the software can be found at in document: How to download Acme Packet Software from the Patches and Updates section of My Oracle Support <Document 1617976.1>
References<BUG:22474551> - TEMPERATURE SENSOR CPU<NOTE:1589489.1> - How to Capture all Log Files on Acme Packet systems including 3800, 4500, 4600, 6100, 6300 <NOTE:1617976.1> - How to download Acme Packet Software from the Patches and Updates section of My Oracle Support Attachments This solution has no attachment |
||||||||||||||||||||
|