Solution  2189648.1 :   PDB Restore Started Via GUI Hangs On Lab System  


Related Items
  • Oracle Communications EAGLE (Hardware)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec OS EPAP ECAP
  •  




In this Document
Symptoms
Cause
Solution
References


Created from <SR 3-9308969097>

Applies to:

Oracle Communications EAGLE (Hardware) - Version EPAP 15.0 and later
Information in this document applies to any platform.

Symptoms

PDB restore started via GUI hangs when PDBA sites are mated.

Cause

Since the restore is initiated from the GUI, there is no opportunity for interaction to respond to the question: "Restore both the local AND remote PDBA? [Highly recommended] (Y/n/q)".

tail restorePdb.out.12419
This script will replace the existing PDB with one provided from a backup and copy the restored backup to the remote.
Are you sure you want to do continue? (y/n) y

Enter the name of the backup tar.gz file. /var/TKLC/appl/free/pdbBackup_epap3ate_20140704111502_DBBirthdate_20110324094638GMT_DBLevel_4556788_v7.25.bkp.tar.gz
Mon Jul 7 15:03:53 CEST 2014
localIp = 10.21.71.194
localName=epap1ate
remoteIp = 10.21.71.196
remoteName=epap2ate
Restore both the local AND remote PDBA? [Highly recommended] (y/n/q)
 
script hangs waiting for response to internal prompt

Solution

Upgrade to EPAP 16.1

References

<BUG:19331057> - SR: EPAP 15 PDB RESTORE STARTED VIA GUI HANGS WHEN PDB SITES ARE MATED