![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2185745.1 : LTO - Backup Failing With Write Error on Drive and Frequently Asking for Cleaning
In this Document
Created from <SR 3-13372361101> Applies to:Sun StorageTek SL500 Modular Library System - Version All Versions and laterLTO Tape Drive - Version All Versions and later Information in this document applies to any platform. SymptomsBackup failing with write error on drive and frequently asking for cleaning. 2016-09-21 13:35:00 Drive_Bay12(0,4,2,9) 3311 "Destination address is occupied" Changes
CauseExpired cleaning cartridge. SolutionReplace expired cleaning cartridge. Created from <SR 3-13372361101> Applies to:Sun StorageTek SL500 Modular Library System Attachments This solution has no attachment |
||||||||||||||||||||
|