In this Document
Symptoms
Changes
Cause
Solution
References


Created from <SR 3-13371305161>

Applies to:

Oracle Communications Performance Intelligence Center (PIC) Software - Version 10.2.0 and later
Information in this document applies to any platform.

Symptoms

pre and post upgrade sanity check script are failing. For example:

# /opt/nsp/scripts/procs/post_upgrade_sanity_check.sh
B E G I N O F P O S T - U P G R A D E S A N I T Y C H E C K P R O C E D U R E
B E G I N S A N I T Y C H E C K : Thu Sep 22 14:39:16 GST 2016
: error: /usr/TKLC/plat/lib/tklcstdlib.sh not found.

Changes

System is upgraded or installed on PIC 10.2.

Cause

MGMT is installed on Oracle Linux and some TPD packages, that are used by the script, are no more present.

Solution

Steps will be removed from documentation. Meanwhile, these scripts must not be used.
 

References

<BUG:24673399> - INCREMENTAL UPGRADE HEALTH CHECK FAILS ON STD SERV

Attachments