Asset ID: |
1-72-2184777.1 |
Update Date: | 2017-06-29 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
2184777.1
:
EPAP Connection Lost At The STP
Related Items |
- Oracle Communications EAGLE (Software)
|
Related Categories |
- PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec OS EPAP ECAP
|
In this Document
Created from <SR 3-13126319943>
Applies to:
Oracle Communications EAGLE (Software) - Version EPAP 16.0 and later
Information in this document applies to any platform.
Symptoms
The EPAP connection gets lost at the STP during the 'maint' process.
Cause
Based on the available logs, issue started because of an error with the 'maint' process.
The maint process received a termination signal at approximately 08/02/16-22:17:49. However, it seems that the maint process did not fully terminated even though it was not functioning properly.
Solution
Restarted the software.
Attachments