Solution Type  Problem Resolution Sure

Solution  2184773.1 :   Oracle Key Manager (OKM) 3.1 - OKM Manager fails with error Ordinal Not found. The ordinal 4445 could not be located in the dynamic link library LIBEAY32  


Related Items
  • Oracle Key Manager
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Backup Software-Filesystems>SN-TP: Encryption
  •  




In this Document
Symptoms
Changes
Cause
Solution


Applies to:

Oracle Key Manager - Version 2.5 to 3.1 [Release 2.0 to 3.0]
Information in this document applies to any platform.

Symptoms

 OKM Manager GUI fails to open with error - Ordinal Not Found The ordinal 4445 could not be located in the dynamic link library LIBEAY32.dll

Changes

 Upgrade of OKM Manager GUI from previous version to version 3.1

Cause

Previous version of OKM Manager was not un-installed prior to installing new version.

OKM Manager 3.1 OpenSSL was removed from OKM Manager install, users must install OpenSSL from an OpenSSL vendor, see the following document:

Oracle Key Manager 3.1 - OpenSSL Distribution Is No Longer Included In GUI Installations(Doc ID 2138532.1)

Install of 3.1 over previous versions leaves incompatible OpenSSL dll files

Solution

Un-install previous version of OKM Manager and install new version.

Use the Uninstall_Oracle_Key_Manager.exe program under the Oracle Key Manager installation directory.