Symptoms
Cause
Solution


Created from <SR 3-13284217431>

Applies to:

Oracle Communications EAGLE (Software) - Version EAGLE 41.x and later
Information in this document applies to any platform.

Symptoms

Since the upgrade to 46.3, the Bus B is regularly  fluctuating.

Cause

- The MIM cards 1211 and 4201 were generating too much noise on the IMT bus, and likely depending on the number of cards using the Bus A or the Bus B, the corresponding bus was rebooting to clear the issue.

- Also, 2 x STC cards are producing many errors on the IMT bus :
Statistics taken the 09/08/2016 and cumulated over 30 min :

Card: H'00ce slot 5217 Type=STC
Rx CRC Error 1836
Pri Ctrl Rx Err 704
Violation Error 5748
Card: H'00cf slot=5218 Type=STC
Rx CRC Error 6024
Pri Ctrl Rx Err 754
Violation Error 878


- 2 x HIPR2 cards indicated some congestion, please check this UAM once you will have replaced the two STC cards 5217 and 5218.

  eaglestp 16-07-29 20:23:03 IST EAGLE5 45.0.0-64.70.31
* 4361.0030 * CARD 1109 HIPR2 HIPR2 detected a minor Congested Second

  eaglestp 16-07-29 23:15:22 IST EAGLE5 45.0.0-64.70.31
** 0782.0031 ** CARD 2310 HIPR2 HIPR2 detected a major Congested Second

  eaglestp 16-07-29 23:15:50 IST EAGLE5 45.0.0-64.70.31
** 0906.0031 ** CARD 2310 HIPR2 HIPR2 detected a major Congested Second

 
= Several cards are indicating issues which are impacting the IMT bus
 

Solution

- Replace the two MIM cards producing errors on the IMT bus (rept-imt-lvl1)
- Clear the important IMT errors produced by the 2 x STC cards, by replacing them
- Check the stop of the IMT congestion on HIPR2 cards 1109 and 2310 after the errors on the IMT bus are cleared.
- Monitor every day for 2 weeks the obits to check the card 1217 is not rebooting with the module “pmtc_mgr.c” (rtrv-obit:loc=:num=10 to get the latest 10 x Obits)

 