![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Problem Resolution Sure Solution 2183689.1 : SL30000/SL8500 - Library “SelfTest” Diagnostics Fails With the Option “Disruptive”
In this Document
Oracle Confidential PARTNER - Available to partners (SUN). Applies to:Sun StorageTek SL3000 Modular Library System - Version All Versions and laterSun StorageTek SL8500 Modular Library System - Version All Versions and later StorageTek Library Console - Version 4.75 and later Information in this document applies to any platform. StorageTek Library Console - Version 6.65. SymptomsLibrary “SelfTest” diagnostics fails with the option “Disruptive” CauseDue to a code bug in SLC_6.65 which was released mandatory for the SL3000 code 4.40. This problem in SLC-6.65 affects both the SL3000 and SL8500. SolutionWill be addressed in an upcoming SLC code release. In the interim SLC_6.51 can be used to run the Disruptive SelfTest. Note: (27-Oct, 2016) SLC-6.60 is the required level for SL8500 FRS-8.51. You do not need to install SLC-6.65 on the SL8500. Attachments This solution has no attachment |
||||||||||||||||
|