Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2183689.1
Update Date:2017-11-14
Keywords:

Solution Type  Problem Resolution Sure

Solution  2183689.1 :   SL30000/SL8500 - Library “SelfTest” Diagnostics Fails With the Option “Disruptive”  


Related Items
  • Sun StorageTek SL3000 Modular Library System
  •  
  • Sun StorageTek SL8500 Modular Library System
  •  
  • StorageTek Library Console
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
  •  




In this Document
Symptoms
Cause
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential for Service Personnel

Applies to:

Sun StorageTek SL3000 Modular Library System - Version All Versions and later
Sun StorageTek SL8500 Modular Library System - Version All Versions and later
StorageTek Library Console - Version 4.75 and later
Information in this document applies to any platform.

StorageTek Library Console - Version 6.65.

Symptoms

 Library “SelfTest” diagnostics fails with the option “Disruptive”

Cause

 Due to a code bug in SLC_6.65 which was released mandatory for the SL3000 code 4.40.  This problem in SLC-6.65 affects both the SL3000 and SL8500.

Solution

Will be addressed in an upcoming SLC code release. In the interim SLC_6.51 can be used to run the Disruptive SelfTest.

Note: (27-Oct, 2016) SLC-6.60 is the required level for SL8500 FRS-8.51. You do not need to install SLC-6.65 on the SL8500.

Image 1

Image 2


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.