![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2182960.1 : Using the Ethernet Virtual Functionality causes "panic[cpu0]/thread=2a10009bb80: Fatal error has occurred in: PCIe fabric.(0x1)(0x43)"
In this Document
Applies to:Fujitsu M10-1 - Version All Versions to All Versions [Release All Releases]Fujitsu M10-4 - Version All Versions to All Versions [Release All Releases] Fujitsu M10-4S - Version All Versions to All Versions [Release All Releases] Information in this document applies to any platform. SymptomsThe device property, pcie-ari-supported, is not properly created. Example of panic message: panic[cpu0]/thread=2a10009bb80: Fatal error has occurred in: PCIe fabric.(0x1)(0x43)
Changes
CauseThis problem is caused by an XSCF firmware bug introduced in XCP2280.
SolutionThis bug is fixed in XCP2320. Please apply the fixed XCP firmware. There are two workarounds:
If system panic repeats, please apply the fixed XCP firmware after stopping the system (or PPAR) by the poweroff XSCF command References<NOTE:1554086.1> - Fujitsu M10-1/M10-4/M10-4S XSCF Control Package (XCP) Firmware Image Software Version Matrix InformationAttachments This solution has no attachment |
||||||||||||||||||||
|