Created from <SR 3-13233880211> Applies to:Oracle Communications EAGLE (Software) - Version EAGLE 3x.x and laterInformation in this document applies to any platform. SymptomsThe Links of one particular LSN (Linkset) are bouncing > rept-stat-slk:loc=xxx:l2stats=both In Service 16-08-26 08:54:07.485
CauseThere are regular congestion and discards on the links. 2560.0264 SLK 6114,A5 REPT-LINK-CGST: congestion level 0 to 1
****16-08-25 19:50:52**** 2561.0265 SLK 6114,A5 REPT-LINK-CGST: congestion level 1 to 2 ****16-08-25 19:50:52**** 2562.0266 SLK 6114,A5 REPT-LINK-CGST: congestion level 2 to 3 ****16-08-25 19:50:53**** 2563.0270 SLK 6114,A5 REPT-LINK-CGST: discard level 0 to 1 ****16-08-25 19:50:53**** 2564.0271 SLK 6114,A5 REPT-LINK-CGST: discard level 1 to 2 ****16-08-25 19:50:53**** 2569.0272 SLK 6114,A5 REPT-LINK-CGST: discard level 2 to 3
****16-08-25 19:49:07****
2076.0116 * SLK 6114,A5 Link expected IP TPS threshold exceeded SolutionThe issue has been resolved by increasing the IPTPS value from 200 to 400. Attachments This solution has no attachment |
||||||||||||||||
|