Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2180223.1
Update Date:2016-09-13
Keywords:

Solution Type  Problem Resolution Sure

Solution  2180223.1 :   The Links of a Sigtran Linkset Are Bouncing  


Related Items
  • Oracle Communications EAGLE (Software)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec Eagle 5
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-13233880211>

Applies to:

Oracle Communications EAGLE (Software) - Version EAGLE 3x.x and later
Information in this document applies to any platform.

Symptoms

The Links of one particular LSN (Linkset) are bouncing

> rept-stat-slk:loc=xxx:l2stats=both

In Service 16-08-26 08:54:07.485
IP Connection failure 16-08-26 08:57:56.425
In Service 16-08-26 09:11:15.500
IP Connection failure 16-08-26 09:13:04.040
In Service 16-08-26 09:26:16.505
IP Connection failure 16-08-26 09:28:41.485
In Service 16-08-26 09:41:56.515
IP Connection failure 16-08-26 09:44:07.590
In Service 16-08-26 09:57:31.520
IP Connection failure 16-08-26 09:59:29.505
In Service 16-08-26 09:59:53.530
IP Connection failure 16-08-26 10:00:26.120
In Service 16-08-26 10:13:42.525
IP Connection failure 16-08-26 10:14:53.630
In Service 16-08-26 10:28:08.540
IP Connection failure 16-08-26 10:30:03.835

 

Cause

There are regular congestion and discards on the links.
Also the IPTPS (IP Transaction Per Second) seems to be too high for the links. The far end configuration has to be checked.
 

  2560.0264 SLK 6114,A5 REPT-LINK-CGST: congestion level 0 to 1
  ****16-08-25 19:50:52****
  2561.0265 SLK 6114,A5 REPT-LINK-CGST: congestion level 1 to 2
  ****16-08-25 19:50:52****
  2562.0266 SLK 6114,A5 REPT-LINK-CGST: congestion level 2 to 3
  ****16-08-25 19:50:53****
  2563.0270 SLK 6114,A5 REPT-LINK-CGST: discard level 0 to 1
  ****16-08-25 19:50:53****
  2564.0271 SLK 6114,A5 REPT-LINK-CGST: discard level 1 to 2
  ****16-08-25 19:50:53****
  2569.0272 SLK 6114,A5 REPT-LINK-CGST: discard level 2 to 3

 

  ****16-08-25 19:49:07****
  2076.0116 * SLK 6114,A5 Link expected IP TPS threshold exceeded

 
 

Solution

The issue has been resolved by increasing the IPTPS value from 200 to 400.
 


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.