Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2179662.1
Update Date:2016-09-05
Keywords:

Solution Type  Problem Resolution Sure

Solution  2179662.1 :   Diameter Signaling Router (DSR) - Wrong Values for Measurement Parameters "TmAnswerTimeAvg" & "TmAnswerTimePeak" in MP Performace Report  


Related Items
  • Oracle Communications Diameter Signaling Router (DSR)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec DSR
  •  




In this Document
Symptoms
Cause
Solution
References


Created from <SR 3-13212922922>

Applies to:

Oracle Communications Diameter Signaling Router (DSR) - Version DSR 7.0.1 and later
Tekelec

Symptoms

Very high value for MP Performance KPI TmAnswerTimeAvg & TmAnswerTimePeak

TmAnswerTimeAvg is defined as Average time (in milliseconds) to process an Answer message. This is the time from when a Diameter Answer message is read from the ingress peer's SCTP/TCP socket until it is sent to the egress peer’s SCTP/TCP socket.

TmAnswerTimePeak is defined as Peak time (in milliseconds) to process an Answer message. This is the time from when a Diameter Answer message is read from the ingress peer’s SCTP/TCP socket until it is sent to the egress peer’s SCTP/TCP socket.

Here is sample from MP performance report showing high value:

Report Type: MeasSimple
Report Date:
Product: Oracle Communications Diameter Signaling Router 7.0.1.0.0-70.28.0
Report Description:
Scope: SOAM
Group: MP Performance
Interval:
Start:
End:
Count:

Timestamp                  Scope Type   Scope    Server     TmAnswerTimeAvg     TmAnswerTimePeak
2016-08-31 07:00:00 CDT    NE           SOAM     MP1        3060078283             4292843555
2016-08-31 08:00:00 CDT    NE           SOAM     MP1        2495628730             4292843555
2016-08-31 09:00:00 CDT    NE           SOAM     MP1        2111400149             4292843556

 

 

Cause

  • This is a known Bug
  • Bug# 21627900 - Cross-DSR timing measurements incorrect

 

Solution

  • “Bug# 21627900 - Cross-DSR timing measurements incorrect” is fixed in DSR 7.1.1.0.0_71.27.0 or higher release.
  • It is recommended to upgrade to DSR 7.1.1.0.0_71.27.0 or higher release to fix this issue

 

References

<BUG:21627900> - CROSS-DSR TIMING MEASUREMENTS INCORRECT

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.