![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2178310.1 : T10000B - REPORTED READ DATA CHK: 08402023174528203700"4056 4056 4056 4056"
In this Document
Created from <SR 3-13162893781> Applies to:Sun StorageTek T10000B Tape Drive - Version All Versions and laterSun StorageTek VSM5 System - Version All Versions and later Information in this document applies to any platform. SymptomsThe customer is getting several messages with FSC 4056 on T10000B (RTD) with firmware 1.52.203. The VSM5 is swapping the MVC to other RTD and got same message. CauseBy VSM5 log, we can see: The problem is occurring in different RTD and same MVC and the drive is can not locate the ALP position 00023. REC: 4386 16/08/11 at 08:13:41 06/C012/P0 SNS 23(Read Data Check), 27(back space block), fsc(4056), MVC:001114 REC: 4377 16/08/11 at 08:02:04 00/C002/P0 SNS 23(Read Data Check), 27(back space block), fsc(4056), MVC:001114
MODEL = T10000B FSC: 4056 RO_FSC_READ_PAST_TMK MIM Code: NONE FRU: MICROCODE CONF: 100% Summary: |INVALID UCODE |FUNC NOT IMPL | *** | Field Text:
SolutionUpgrade firmware of all drives to 1.52.206. References<BUG:24466516> - ITAU-4056 ERRORS ON MULTIPLE TAPES AND DRIVESAttachments This solution has no attachment |
||||||||||||||||||
|