![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Problem Resolution Sure Solution 2177894.1 : Congestion On 2 Linksets Toward The Same Destination
In this Document
Created from <SR 3-13106581838> Applies to:Oracle Communications EAGLE (Hardware) - Version EAGLE 3x.x and laterInformation in this document applies to any platform. SymptomsCongestion events are observed on 2 linksets toward the same far end CauseThe far end is having congestion > pass:loc=2115:cmd="linkinfo -l a10"
eagle 16-08-01 15:13:35 BST EAGLE5 45.0.1-64.70.35 16-08-01 15:10:38.215 M2PA_LSR_RECEIVED 16-08-01 15:10:39.290 M2PA_LSB_RECEIVED 16-08-01 15:10:39.390 M2PA_LSB_RECEIVED 16-08-01 15:10:39.490 M2PA_LSB_RECEIVED 16-08-01 15:10:39.595 M2PA_LSB_RECEIVED 16-08-01 15:10:39.695 M2PA_LSB_RECEIVED
****16-08-01 15:17:07****
8493.0241 ** SLK 2215,A11 REPT-LKF: rcvd remote out of service ****16-08-01 15:17:00**** 8451.0200 SLK 2215,A11 RCVRY-LKF: link available ****16-08-01 15:16:52**** 8399.0241 ** SLK 2215,A10 REPT-LKF: rcvd remote out of service ****16-08-01 15:16:51**** 8388.0200 SLK 2215,A10 RCVRY-LKF: link available ****16-08-01 15:16:49**** 8376.0241 ** SLK 2115,A10 REPT-LKF: rcvd remote out of service
****16-08-01 00:00:29****
7961.0216 ** SLK 2115,A11 REPT-LKF: remote congestion timeout ... eagle 16-08-01 03:49:11 BST EAGLE5 45.0.1-64.70.35 ** 9187.0216 ** SLK 2115,A11 ygl REPT-LKF: remote congestion timeout SLC=00 FECLLI=ygl CLASS=IPVHSL
SolutionThere is nothing to do on the Eagle side. The issue has been solved on the far end by increasing the MAXSLKTPS capacity of the links which was too low for the sudden experienced peak of traffic. Attachments This solution has no attachment |
||||||||||||||||
|