Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2177687.1
Update Date:2017-05-10
Keywords:

Solution Type  Problem Resolution Sure

Solution  2177687.1 :   Install of ODA X6-2S/M/L Using 12.1.2.7.0 or 12.1.2.8.0 Fails to start Web Console: "Open a browser, and enter the following URL to launch the Web Console:" Does Not Work  


Related Items
  • Oracle Database Appliance X6-2 HA Hardware
  •  
  • Oracle Database Appliance Software
  •  
Related Categories
  • PLA-Support>Eng Systems>Exadata/ODA/SSC>Oracle Database Appliance>DB: ODA_EST
  •  


The new ODA X6-2s (small and X6-2m (medium) shipped originally with 12.1.2.7.0. However, with 12.1.2.8.0 available, it is faster and cleaner to install X6-2sm rather than upgrade. This note confirms downloads ISO and GI for X6-2s / X6-2m for 12.1.2.8 is the preferred method. Additionally, the newer CPU patched  12.1.0.2.160719 and 11.2.0.4.160719 RDBMS Clones can be immediately used.

In this Document
Symptoms
Changes
Cause
Solution
References


Created from <SR 3-13253531791>

Applies to:

Oracle Database Appliance X6-2 Hardware - Version All Versions to All Versions [Release All Releases]
Oracle Database Appliance Software - Version 12.1.2.7 to 12.1.2.8 [Release 12.1]
Information in this document applies to any platform.

Symptoms

The following error reports while trying to apply the 12.1.2.8 GI is failing on a new X6-2s or X6-2m

# /opt/oracle/dcs/bin/odacli update-repository -f /tmp/rdbms/oda-sm-12.1.2.8.0-160817-GI-12.1.0.2.zip
-bash: /opt/oracle/dcs/bin/odacli: No such file or directory

 Factors:

  • ODA X6-2s or ODA 6-2m
  • Using default ODA version of 12.1.2.7
  • Attempting to upgrade to 12.1.2.8

Probable indicators

  • New from the ODA X6-2s or X6-2m factory installation 
  • No patching attempted since receiving the ODA X6-2s or X6-2m
  • Have not applied the Patch 24391174 ORACLE DATABASE APPLIANCE X6-2 S AND X6-2 M 12.1.2.8 DCSIMAGE DOWNLOAD

UNABLE to START X6-2 GUI to complete the Web Deployment
From IE

This page ca't be displayed
From Chrome

This site can't provide a secure connection

The preferred browser is FireFox:
Using FireFox would expose the error message regarding SSL being associated with the failure leading to the finding that this is a known issue

Changes

 Brand new box and applying the August 2016 12.1.2.8 GI bundle.

Cause

New ODA X6-2s /X6-2m servers do not include a complete installation from the factory.

The 12.1.2.7 installation will require completing the steps for the GI and other patches*.

See: Note 888888.1  for the most current information on upgrades for the ODA

* If upgrading from 12.1.2.7 to 12.1.2.8 you will also need Patch 24391174 ORACLE DATABASE APPLIANCE X6-2 S AND X6-2 M 12.1.2.8 DCSIMAGE DOWNLOAD

Solution



Please download the ISO image for the X6-2s

12.1.2.8

23530609 Oracle Database Appliance Software: Patch
ORACLE DATABASE APPLIANCE X6-2 S and X6-2 M 12.1.2.8.0 OS ISO IMAGE



Then apply

12.1.2.8

23494985 Oracle Database Appliance Software: Patch
ORACLE DATABASE APPLIANCE X6-2 S and X6-2 M 12.1.0.2.160719 GI Clone


Related RDBMS clones:

12.1.2.8

a) 23494997 Oracle Database Appliance Software: Patch
ORACLE DATABASE APPLIANCE X6-2 S and X6-2 M 11.2.0.4.160719 RDBMS Clone

b) 23494992 Oracle Database Appliance Software: Patch
ORACLE DATABASE APPLIANCE X6-2 S and X6-2 M 12.1.0.2.160719 RDBMS Clone 

 

 

References

<BUG:24391174> - ODALITE: ORACLE DATABASE APPLIANCE X6-2 S AND X6-2 M 12.1.2.8 DCSIMAGE DOWNLOAD
<NOTE:888888.1> - Oracle Database Appliance - 12.1.2 and 2.X Supported ODA Versions & Known Issues