Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2175732.1
Update Date:2017-11-14
Keywords:

Solution Type  Problem Resolution Sure

Solution  2175732.1 :   SL8500 - Drive Not Unloaded For Fetch, FSC 1107  


Related Items
  • Sun StorageTek SL8500 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
  •  




In this Document
Symptoms
Changes
Cause
Solution
References


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential for Service Personnel
Created from <SR 3-13178761168>

Applies to:

Sun StorageTek SL8500 Modular Library System - Version All Versions and later
Information in this document applies to any platform.

Symptoms

The drives are getting messages RewindUnload

Cartridges are sticking on drives

The ASR is opening the SR with FSC(1107): Drive not unloaded for fetch - on rewindUnload

************* ADDITIONAL INFORMATION *************
*** Alarm Description ***
FSC(1107): Drive not unloaded for fetch - on rewindUnload, hliLsm=2
Suspected Device Address :1.3.2.1.1
"Drive not unloaded for fetch - on rewindUnload", hliLsm=2
Device Dmod: 516000200xxx
Tray SN: 516000200xxx
Device Model: SL8500

Changes

 The customer replaced the Ethernet Switches

Cause

Configuration issue on switch port.

Solution

Check the Log SnapShot in SPLAT for the message below:

In Summary: Library port eth0 is connected at 100 Mbps Half Duplex

In WEB Display: 3983 "Pli socket closed without cancel", exception=java.net.SocketException: Connection reset queryCartrid root default 25629601

The ACS is Disconnected.

Asked the customer to configure the Switch port to Auto-Negotiate, Full Duplex and Reboot the library by controller.

References

<NOTE:1018374.1> - SL8500 - What are the Specifications for the TCP/IP Customer Interface Connection for SL8500?
<NOTE:1514930.1> - SL3000/SL8500 - Rewind/Unload FAILED - Drive is Loaded
<NOTE:2072612.1> - SL8500 - ACS DISCONNECTED
<NOTE:1536185.1> - SL8500 - HBC 2A and 2B Port Speed and Host Settings

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback