Solution Type Problem Resolution Sure Solution 2175499.1 : SL150 - Status Degraded on Different Power Supplies
In this Document
Created from <SR 3-12169264971> Applies to:StorageTek SL150 Modular Tape Library - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. SymptomsStatus Degraded on different Power Supplies. D Present Status 2016-02-11T10:29:46.089, 0.0.0.0.0, 000, EnvMon, , error, 0000, 9003, "PS FAULT (Module power supply Status Word indicates the Power Supply is Off or Unplugged): module:1 position:1, statusWord:0x40, firmwareVersion:0x540" 2016-02-11T10:30:53.035, 0.0.0.0.0, 000, EnvMon, , warn, 0000, 9005, "PS WARNING (Module power supply Status Word indicates a Warning with the PS input): module:3 position:1, statusWord:0x2000, firmwareVersion:0x540" 2016-02-11T10:32:11.030, 0.0.0.0.0, 000, EnvMon, , error, 0000, 9003, "PS FAULT (Module power supply Status Word indicates the Power Supply is Off or Unplugged): module:2 position:2, statusWord:0x40, firmwareVersion:0x540" CauseProblem with the Controller Card in the robotic module. Solution1. Reseat all of the PSUs. Take them out one at a time and replace them again. 2. Reboot the library. 3. Swap PSUs with working PSUs. If PSUs come to life suspect the robot. 4. If there is a new failure on these PSUs replace all PSUs with status Degraded. 5. Should the problem persist, replace the robotic module.
References<NOTE:1473774.1> - SL150 - How to Remove/Replace the Robot CRU in a StorageTek SL150 Modular Tape Library [VCAP]Attachments This solution has no attachment |
||||||||||||||||||
|