![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Problem Resolution Sure Solution 2175292.1 : T10000 - 2C03 SNO Errors
In this Document
Oracle Confidential PARTNER - Available to partners (SUN). Applies to:Sun StorageTek T10000 Tape Drive - Version All Versions and laterSun StorageTek T10000A Tape Drive - Version All Versions and later Sun StorageTek T10000B Tape Drive - Version All Versions and later Information in this document applies to any platform. Symptoms2C03 SNO FSC Errors CauseFSC Dictionary Description: FSC: 2C03 ASC_FSC_FICON_IURCV_BUFF_FREE_UNUSED MIM Code: POTENTIAL FRU: MICROCODE CONF: 100% FRU: HARDWARE CONF: 0% Summary: |BUFF ERROR |DETECTED | *** | Field Text:
SolutionT10000A/B/C/D - FSC 2C03 SNO - Ensure that "Single Ready Alert" is ENABLED on all T10KA/B devices. This setting will minimize 2C03 failures on T10KA/Bs. This change was introduced in 1.52.103/203 code for T10000A/B drives. Go to the VOP Fibre Tab and verify this feature is enabled at the bottom of that tab. This feature is automatically ENABLED on all C & D devices and is not shown in VOP for these models. This feature was introduced with 3.62.109 code for T10000C drives. You need to be at 4.11.111 code if you are see these errors on T10000D drives. See bug 23009483. Attachments This solution has no attachment |
||||||||||||||||
|