Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2173747.1
Update Date:2016-08-22
Keywords:

Solution Type  Problem Resolution Sure

Solution  2173747.1 :   Oracle Key Manager (OKM) - X4170 m2 KMA Encounters ILOM Browser Timeouts With ILOM Firmware 1.7.6  


Related Items
  • Sun StorageTek Crypto Key Management System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Backup Software-Filesystems>SN-TP: Encryption
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-13201291931>

Applies to:

Sun StorageTek Crypto Key Management System - Version All Versions and later
Information in this document applies to any platform.

Symptoms

 After several minutes of being logged in to the ILOM via a browser, the session will timeout and become unusable.

Cause

Upgraded ILOM on x4170 m2 KMA to 1.7.6 version.

Patch 23170928: X4170 M2 SW 1.7.6 - ILOM AND BIOS

Solution

Due to the issues encountered with the ILOM 1.7.6 firmware version on X4170 M2 KMA's, the currently recommended firmware version is:

Patch 21745710: X4170 M2 SW 1.7.5 - ILOM AND BIOS

 