Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2168620.1
Update Date:2018-03-01
Keywords:

Solution Type  Problem Resolution Sure

Solution  2168620.1 :   L1400 - Failing with FSCs 3088, 309F ,3104 and 3007, Library Will Not Initialize  


Related Items
  • Sun StorageTek L1400 Tape Library
  •  
  • Sun StorageTek L700e Tape Library
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK Legacy Drive and Library
  •  




In this Document
Symptoms
Changes
Cause
Solution
 Applies to:


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential for Service Personnel
Created from <SR 3-13082556678>

Applies to:

Sun StorageTek L700e Tape Library - Version All Versions and later
Sun StorageTek L1400 Tape Library - Version All Versions and later
Information in this document applies to any platform.

This library was working until I took several parts out of it to trouble shoot a down L700. The column assembly, hand assemblyy, theta motor and one DC power were taken out. The library gets FSCs 3088,309f,3104 & 3007. I have replaced the hand assy, mpc board(twice), theta motor, z motor, Z flex cable, signal cable(pn:300079201), PRX and PRY cards. I tried to order Robotic power cable, pn:300079302. Apparently this is not available to order anymore. I also have moved the power cables to 2 different sources. Still get same FSCs.

Symptoms

L1400 is not coming online.

The library gets FSCs 3088,309F, 3104 & 3007.

Changes

 

Cause

 Multiple parts replaced for different issues.

FSC definitions.....

&&3007
ERR_LIBRARY_IPL,
The library has started an IPL either by reset or power cycle.
FRU: LOCATION: CONFIDENCE %:
NONE NONE 100

SEVERITY - warn

&&331b
ERR_AUD_SCAN_RESPONSE_TIMEOUT,
No message received from scan process.
FRU: LOCATION: CONFIDENCE %:
Fatal Logical Err S/W 99
MPC LCU 01

SEVERITY - warn

&&3322
ERR_AUD_INVALID_READ_STATUS,
Invalid Condtion Software Error.
FRU: LOCATION: CONFIDENCE %:
Logical Error S/W 99
MPC LCU 01

SEVERITY - warn

&&3317
ERR_AUD_USER_RESPONSE_TIMEOUT,
Software error occurred in packet being sent to audit task.
FRU: LOCATION: CONFIDENCE %:
Logical Error S/W 99
MPC LCU 01

SEVERITY - warn

&&3098
ERR_SRV_REQUEST_ALREADY_ACTIVE_AGAINST_MECHANISM,
Request rejected - motion is already active against mechanism
FRU: LOCATION: CONFIDENCE %:
Logical Error S/W 99

SEVERITY - warn

 

Solution

The Theta Coil cable located at the top of the z-assembly is defective and needs to be replaced.

FRU [FRU] 003-2860-01 STK, , 419711301 , N,CBL ASSY, Production 50
Cable [Cable] 419711301 [Has Attachments] CBL ASSY,COIL,THETA Production
This is the part that should be ordered.

As this product is EOL, the part may need to be ordered via the NOPRT process.


Created from <SR 3-13082556678>

Applies to:

Sun StorageTek L700e Tape Library
1-914CU


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.