Solution Type  Problem Resolution Sure

Solution  2168250.1 :   Exalytics Encounters Error when Attempting to Boot from Release 2.0.0.0.0 Image - "No Driver Found"  


Related Items
  • Exalytics In-Memory Machine X4-4
  •  
Related Categories
  • PLA-Support>Eng Systems>Exalytics>Oracle Exalytics>DB: Exalytics_EST
  •  




Created from <SR 3-13113998891>

Applies to:

Exalytics In-Memory Machine X4-4 - Version All Versions to All Versions [Release All Releases]
Linux x86-64

Symptoms

Attempting to upgrade an existing Exalytics X4-4 server to Release 2.0.0.0.0 by following the steps in the Installation Guide.  After booting the machine with the CD ROM and after passing a couple of screens, installation gets stuck and reports error:

"No Driver Found"

Cause

Upgrade attempt.

Solution

You may workaround this error by proceeding with the installation as described below.

Reboot from the image, but when the installer comes up with "boot:" type the following command:

linux all-generic-ide irqpoll pci=nommconf

Press enter and the installation can than be completed.
 

 