![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 2168250.1 : Exalytics Encounters Error when Attempting to Boot from Release 2.0.0.0.0 Image - "No Driver Found"
Created from <SR 3-13113998891> Applies to:Exalytics In-Memory Machine X4-4 - Version All Versions to All Versions [Release All Releases]Linux x86-64 SymptomsAttempting to upgrade an existing Exalytics X4-4 server to Release 2.0.0.0.0 by following the steps in the Installation Guide. After booting the machine with the CD ROM and after passing a couple of screens, installation gets stuck and reports error: "No Driver Found" CauseUpgrade attempt. SolutionYou may workaround this error by proceeding with the installation as described below. Reboot from the image, but when the installer comes up with "boot:" type the following command: linux all-generic-ide irqpoll pci=nommconf
Press enter and the installation can than be completed.