Asset ID: |
1-72-2168058.1 |
Update Date: | 2017-05-24 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
2168058.1
:
EPAP Birthday Mismatch
Related Items |
- Oracle Communications EAGLE (Software)
|
Related Categories |
- PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec Eagle 5
|
In this Document
Created from <SR 2-9401156>
Applies to:
Oracle Communications EAGLE (Software) - Version EPAP 16.0 to EPAP 16.0 [Release EPAP 16.0]
Information in this document applies to any platform.
Symptoms
PDB and RTDB Eagle Birthdates when issuing 'rept-stat-db' is showing year 2022
Cause
Software Bug
na
Solution
Upgrade to EPAP 16.1
References
<BUG:22044199> - SR:BIRTHDATE DISPLAY PROBLEM ON EAGLE WITH EPAP 15 AND 16
Attachments