Solution Type  Problem Resolution Sure

Solution  2167395.1 :   UIM 1056 - SCCP Rcvd Inv SCMG - Bad Subsystem  


Related Items
  • Oracle Communications EAGLE (Hardware)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec Eagle 5
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-13072771151>

Applies to:

Oracle Communications EAGLE (Hardware) - Version EAGLE 3x.x and later
Information in this document applies to any platform.

Symptoms

Eagle is receiving the UIM 1056 - SCCP rcvd inv SCMG - bad subsystem
It means Eagle received SCCP management message (SCMG) that was discarded because of an invalid subsystem number (SSN)

eaglestp 16-07-25 10:17:48 EST EAGLE5 44.0.5-64.34.26
3567.1056 CARD 1217 INFO SCCP rcvd inv SCMG - bad subsystem
SIO=d3 OPC= s-12351-aa DPC= s-02005-aa
SCMG: MSG TYPE=003 MSG LEN=005
AFTPC= s-02005-aa     AFTSS=006 MULT=000
LSN=sgsn2
Report Date:16-07-25 Time:10:14:40

 

Cause

The issue is on the SGSN platform side

- s-2005-aa is the PC of the Eagle.
- The SGSN platform is sending SMCG messages to the Eagle with an Affected Point Code (AFTPC) = Eagle's Point code and an Affected SSN = 6.
- Eagle does not have the SSN=6 for itself. This is a SSN number for an HLR platform (Home Location Registration)

=> For which reason the SGSN is sending SCMG messages to the Eagle for an SSN which does not belong to the Eagle ?
=> The issue has to be fixed on the SGSN platform.


 

Solution

The SGSN configuration must be changed so that it stops sending SCMG messages to the Eagle for an SSN which does not belong to the Eagle.
 