Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2167321.1
Update Date:2016-08-08
Keywords:

Solution Type  Problem Resolution Sure

Solution  2167321.1 :   UAM 0537 Ethernet Error Threshold Exceeded  


Related Items
  • Oracle Communications EAGLE (Software)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec Eagle 5
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-13057507711>

Applies to:

Oracle Communications EAGLE (Software) - Version EAGLE 3x.x and later
Information in this document applies to any platform.

Symptoms

The card 2208 is having Ethernet errors :

2605.0537 ** ENET 2208,A Ethernet error threshold exceeded
16-07-21 09:18:12
> rept-stat-card:loc=2208:mode=full

  eaglestp16-07-21 12:54:03 IST EAGLE5 45.0.1-64.70.35

  CARD VERSION     TYPE nGPL  PST   SST    AST
  2208 134-070-035 IPSM IPSHC IS-NR Active -----
  ALARM STATUS = No Alarms.
  ...
  IPLNK STATUS

  IPLNK IPADDR        STATUS   PST
  A     172.30.48.10  ERRORS   IS-ANR

Cause

This is a configuration problem at the IP layer
 
The card 2208 is not configured like the other good one in 4313 slot.
It should not be configured with AUTO=YES. It has to be configured with AUTO=NO, Duplex=Full, Speed=100


 LOC   PORT   IPADDR          SUBMASK         DUPLEX  SPEED  MACTYPE AUTO  MCAST
 2208  A     172.30.48.10    255.255.255.0    ----    ---     DIX    YES   NO

Good configuration :

 LOC   PORT   IPADDR         SUBMASK           DUPLEX SPEED  MACTYPE AUTO   MCAST
 4313  A     172.30.104.130  255.255.255.248   FULL   100     DIX     NO    NO

 

Solution

To reconfigure the card :

- inh-card:loc=2208
- chg-ip-lnk:loc=2208:port=a:auto=no:duplex=full:speed=100
- alw-card:loc=2208

 


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.