![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2162126.1 : SL150 - It Is Not Initializing, Library is Incompatible With the Version of Drives
In this Document
Created from <SR 3-12982709777> Applies to:StorageTek SL150 Modular Tape Library - Version All Versions and laterInformation in this document applies to any platform. First installation , library with FW 2.50, this library came with 8 drives to install IBM LTO 7, but we know that this version of the library is incompatible with the version of drives. FSE can not perform FW upgrade because the drives are not recognized by version 2.50. Can we perform the FW upgrade to 2.60 without these drives? DriveAssembly DRIVE LTO7 IBM FC SymptomsLibrary is incompatible with the version of drives. Unable upgrade from 2.50 to 2.60 with LTO7 drives. ChangesNew installation. CauseLTO7 drives are not recognized in library with 2.50 code as the drives are not supported until 2.60 firmware. SolutionCan the SL150 be upgraded from 2.50 to 2.60 with LTO7 drive as bridge drive?
Applies to:StorageTek SL150 Modular Tape Library - Version All Versions and later Attachments This solution has no attachment |
||||||||||||||||||||
|