Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2159670.1
Update Date:2017-12-21
Keywords:

Solution Type  Problem Resolution Sure

Solution  2159670.1 :   PDBA Instance Seems To Be Restarting On EPAP A  


Related Items
  • Oracle Communications EAGLE (Software)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec OS EPAP ECAP
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-12970413531>

Applies to:

Oracle Communications EAGLE (Software) - Version EPAP 16.0 and later
Information in this document applies to any platform.

Symptoms

Customer noticed that the pdba process was bouncing

Cause

The pdba process had been bouncing since 07/01.
Undertermined

Solution

Stopped the software and killed the pbda process. Restarted the software