Asset ID: |
1-72-2159670.1 |
Update Date: | 2017-12-21 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
2159670.1
:
PDBA Instance Seems To Be Restarting On EPAP A
Related Items |
- Oracle Communications EAGLE (Software)
|
Related Categories |
- PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec OS EPAP ECAP
|
In this Document
Created from <SR 3-12970413531>
Applies to:
Oracle Communications EAGLE (Software) - Version EPAP 16.0 and later
Information in this document applies to any platform.
Symptoms
Customer noticed that the pdba process was bouncing
Cause
The pdba process had been bouncing since 07/01.
Undertermined
Solution
Stopped the software and killed the pbda process. Restarted the software
Attachments
This solution has no attachment