Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2159533.1
Update Date:2017-10-05
Keywords:

Solution Type  Problem Resolution Sure

Solution  2159533.1 :   Oracle ZFS Storage Appliance: Clone of a Replicated Project Fails Due to LUN Number Conflict  


Related Items
  • Sun ZFS Storage 7420
  •  
  • Oracle ZFS Storage ZS3-2
  •  
  • Sun Storage 7110 Unified Storage System
  •  
  • Sun Storage 7210 Unified Storage System
  •  
  • Oracle ZFS Storage ZS4-4
  •  
  • Sun Storage 7410 Unified Storage System
  •  
  • Sun Storage 7310 Unified Storage System
  •  
  • Sun ZFS Storage 7120
  •  
  • Oracle ZFS Storage ZS3-4
  •  
  • Sun ZFS Storage 7320
  •  
  • Oracle ZFS Storage Appliance Racked System ZS4-4
  •  
  • Oracle ZFS Storage ZS3-BA
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>ZFS Storage>SN-DK: ZS
  •  




In this Document
Symptoms
Cause
Solution


Applies to:

Sun Storage 7210 Unified Storage System - Version All Versions and later
Sun Storage 7310 Unified Storage System - Version All Versions and later
Sun Storage 7410 Unified Storage System - Version All Versions and later
Sun ZFS Storage 7120 - Version All Versions and later
Sun ZFS Storage 7320 - Version All Versions and later
7000 Appliance OS (Fishworks)

Symptoms

Cloning a replicated project containing LUNs fails with:

error: Could not complete the action because LU number mapped to a selected
target/initiator group pair conflicts with LU numbers already assigned.
Prevent this error by removing access to the conflicting LUs.

Cause

For any given initiator group, no 2 LUNs can have the same LUN number.

When cloning a replicated project, the administrator has no control over the order in which the project's shares are cloned.

If the cloning order is such that a LUN with "lunumber=auto" is assigned LUN number 0 before the cloning of the LUN with "lunumber=0", we encounter a LUN number conflict and the project cloning operation fails.

 

Note: In the BUI "lunumber=auto" is called "LU POLICY Auto-assign".

Solution

Set all LUNs in the project on the replication source appliance to "lunumber=auto" and allow for the next replication update to complete before attempting again to clone the project.

To ensure that the current LUN numbers, including LUN number 0, remain the same throughout the lifetime of the LUNs, set "fixednumber=true" ("Persist" checkbox in the BUI).

 

The change from "lunumber=0" to "lunumber=auto" and setting "fixednumber=true" can be done online without any disruption.

 