Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2158541.1
Update Date:2018-03-01
Keywords:

Solution Type  Problem Resolution Sure

Solution  2158541.1 :   T10kb Drive Not Functional, FSC: FE01 ITZ_FSC_DC_CMPR_DIAGNOSTIC_FAILED  


Related Items
  • Sun StorageTek T10000B Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
  •  




In this Document
Symptoms
Changes
Cause
Solution
 Applies to:


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential for Service Personnel
Created from <SR 3-12970821971>

Applies to:

Sun StorageTek T10000B Tape Drive - Version All Versions and later
Information in this document applies to any platform.

Symptoms

SL8500 reports drive not functional. Attempted to transition drive online in SLConsole, which also failed.

FSC: FE01 ITZ_FSC_DC_CMPR_DIAGNOSTIC_FAILED

Changes

 

Cause

 Defective drive.

FSC: FE01 ITZ_FSC_DC_CMPR_DIAGNOSTIC_FAILED
MIM Code: INOPERABLE
FRU: HARDWARE CONF: 95%
FRU: MICROCODE CONF: 5%

Summary: |WAKEUP DIAG |FAILED |REGISTER VALUE |
Field Text:
The DC hardware compression wakeup diagnostic failed.

Support Annotations:
T10000a/B - if the drive was recently power cycled and took this error coming up then the drive needs to be replaced. There is a defective chip in the drive. No failure analysis (FA) is necessary on the drive.

Solution

Replaced the drive.


Created from <SR 3-12970821971>

Applies to:

Sun StorageTek T10000B Tape Drive
1-914CU