Symptoms
Cause
Solution


Created from <SR 3-12880911671>

Applies to:

StorageTek T10000D Tape Drive - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

 Incorrect transfer rate is shown in SLC for T10000D drives running at 16 Gb. SLC reports a 10 GB transfer rate vs. 16 Gb. The switch does show the correct 19 Gb transfer rate.

Cause

 A tape drive microcode problem causes this error.

Solution

 Bug 23633433. It was fixed in 4.12.106 release.