Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2155532.1
Update Date:2016-07-01
Keywords:

Solution Type  Problem Resolution Sure

Solution  2155532.1 :   Epap [R16.0] - RTDB Unavailable  


Related Items
  • Oracle Communications EAGLE (Hardware)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec OS EPAP ECAP
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-12120097911>

Applies to:

Oracle Communications EAGLE (Hardware) - Version EPAP 16.0 and later
Information in this document applies to any platform.

Symptoms

On : EPAP 16.0 version, EPAP (Hardware)

Epap [R16.0] - RTDB Unavailable

ERROR
-----------------------
RTDB Mate Unavailable

BUSINESS IMPACT
-----------------------
none

Cause

The software was stopped for the backup but no indication why alarm did not clear when the software restarted.
NA

Solution

Software restarted and alarm cleared.


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback