Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2155130.1
Update Date:2017-08-16
Keywords:

Solution Type  Problem Resolution Sure

Solution  2155130.1 :   SL3000 - After Replacing the PUF Card For FCO 354, One PUF Card (PS 08,09,10 and11) Shows Warning  


Related Items
  • Sun StorageTek SL3000 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
  •  




In this Document
Symptoms
Changes
Cause
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential for Service Personnel
Created from <SR 3-12727422159>

Applies to:

Sun StorageTek SL3000 Modular Library System - Version All Versions and later
Information in this document applies to any platform.

Symptoms

Four Power Supply show warnings after FCO 354.

2016-06-06T12:38:18.491, 0.0.0.0.0, 611, drive-director, , error, 0000, 6314, "Director - powerSupplyStateChange(): DriveTray Power Supply Error: Id 07 (ps 11) acok == 0 dcok == 0 powerFail == 1"
2016-06-06T12:38:18.531, 0.0.0.0.0, 611, drive-director, , error, 0000, 6314, "Director - powerSupplyStateChange(): DriveTray Power Supply Error: Id 08 (ps 10) acok == 0 dcok == 0 powerFail == 1"
2016-06-06T12:38:18.571, 0.0.0.0.0, 611, drive-director, , error, 0000, 6314, "Director - powerSupplyStateChange(): DriveTray Power Supply Error: Id 09 (ps 09) acok == 0 dcok == 0 powerFail == 1"
2016-06-06T12:38:18.611, 0.0.0.0.0, 611, drive-director, , error, 0000, 6314, "Director - powerSupplyStateChange(): DriveTray Power Supply Error: Id 10 (ps 08) acok == 0 dcok == 0 powerFail == 1"

The Power Supplies show a yellow flag is SLConsole.

Changes

 Installed FCO 354

Cause


After the replacement of PUF card for FCO 354 the Power Supplies 08, 09, 10 and 11 went into warning state in SLConsole.

2016-05-16T14:09:37.251 error 0.0.0.0.0 6314 "Director - powerSupplyStateChange(): DriveTray Power Supply Error: Id 07 (ps 11) acok == 0 dcok == 0 powerFail == 1" 611 drive-director error

2016-05-16T14:09:37.291 error 0.0.0.0.0 6314 "Director - powerSupplyStateChange(): DriveTray Power Supply Error: Id 08 (ps 10) acok == 0 dcok == 0 powerFail == 1" 611 drive-director error

2016-05-16T14:09:37.331 error 0.0.0.0.0 6314 "Director - powerSupplyStateChange(): DriveTray Power Supply Error: Id 09 (ps 09) acok == 0 dcok == 0 powerFail == 1" 611 drive-director error

2016-05-16T14:09:37.371 error 0.0.0.0.0 6314 "Director - powerSupplyStateChange(): DriveTray Power Supply Error: Id 10 (ps 08) acok == 0 dcok == 0 powerFail == 1" 611 drive-director error



 

Solution

Replaced the PUF-2 card and checked plug J321/J202.
 


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback