Asset ID: |
1-72-2155130.1 |
Update Date: | 2017-08-16 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
2155130.1
:
SL3000 - After Replacing the PUF Card For FCO 354, One PUF Card (PS 08,09,10 and11) Shows Warning
Related Items |
- Sun StorageTek SL3000 Modular Library System
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
|
In this Document
Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential for Service Personnel
Created from <SR 3-12727422159>
Applies to:
Sun StorageTek SL3000 Modular Library System - Version All Versions and later
Information in this document applies to any platform.
Symptoms
Four Power Supply show warnings after FCO 354.
2016-06-06T12:38:18.491, 0.0.0.0.0, 611, drive-director, , error, 0000, 6314, "Director - powerSupplyStateChange(): DriveTray Power Supply Error: Id 07 (ps 11) acok == 0 dcok == 0 powerFail == 1"
2016-06-06T12:38:18.531, 0.0.0.0.0, 611, drive-director, , error, 0000, 6314, "Director - powerSupplyStateChange(): DriveTray Power Supply Error: Id 08 (ps 10) acok == 0 dcok == 0 powerFail == 1"
2016-06-06T12:38:18.571, 0.0.0.0.0, 611, drive-director, , error, 0000, 6314, "Director - powerSupplyStateChange(): DriveTray Power Supply Error: Id 09 (ps 09) acok == 0 dcok == 0 powerFail == 1"
2016-06-06T12:38:18.611, 0.0.0.0.0, 611, drive-director, , error, 0000, 6314, "Director - powerSupplyStateChange(): DriveTray Power Supply Error: Id 10 (ps 08) acok == 0 dcok == 0 powerFail == 1"
The Power Supplies show a yellow flag is SLConsole.
Changes
Installed FCO 354
Cause
After the replacement of PUF card for FCO 354 the Power Supplies 08, 09, 10 and 11 went into warning state in SLConsole.
2016-05-16T14:09:37.251 error 0.0.0.0.0 6314 "Director - powerSupplyStateChange(): DriveTray Power Supply Error: Id 07 (ps 11) acok == 0 dcok == 0 powerFail == 1" 611 drive-director error
2016-05-16T14:09:37.291 error 0.0.0.0.0 6314 "Director - powerSupplyStateChange(): DriveTray Power Supply Error: Id 08 (ps 10) acok == 0 dcok == 0 powerFail == 1" 611 drive-director error
2016-05-16T14:09:37.331 error 0.0.0.0.0 6314 "Director - powerSupplyStateChange(): DriveTray Power Supply Error: Id 09 (ps 09) acok == 0 dcok == 0 powerFail == 1" 611 drive-director error
2016-05-16T14:09:37.371 error 0.0.0.0.0 6314 "Director - powerSupplyStateChange(): DriveTray Power Supply Error: Id 10 (ps 08) acok == 0 dcok == 0 powerFail == 1" 611 drive-director error
Solution
Replaced the PUF-2 card and checked plug J321/J202.
Attachments
This solution has no attachment