Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2153767.1
Update Date:2017-09-25
Keywords:

Solution Type  Problem Resolution Sure

Solution  2153767.1 :   SL150 - TSM Backup Failing With Message ANR8844E (Error Code=2528)  


Related Items
  • StorageTek SL150 Modular Tape Library
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL150 Library
  •  




In this Document
Symptoms
Cause
Solution
References


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential for service personnel
Created from <SR 3-12893948310>

Applies to:

StorageTek SL150 Modular Tape Library - Version All Versions and later
Information in this document applies to any platform.

Symptoms

Backup is failing with message ANR8844E (ERROR CODE=2528)

 MESSAGE ERROR

Cause

No found message error in SL150 Sevice Log.

Only the firmware of the drives and library in down level.

The customer made the firmware upgrade and the error persisted.

In Service log is not showing error during mounts. See image below:

Service Log

In log_drive02_tape.1 we can see that the server is not allocated the data_path. See the picture below:

DATA PATH
 

 

Solution

Delete and redefine the paths on Tivoli Storage Manager.

Once completed, perform backup / restore testing.
 

References

<NOTE:1952297.1> - SL150 – How to Update the Tape Drive Firmware via WEB BUI
<NOTE:1474172.1> - SL150 - How to Find Firmware Update Patches and Upgrade the StorageTek SL150 Modular Tape Library With Those Firmware Patches

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.