Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2153585.1
Update Date:2017-09-26
Keywords:

Solution Type  Problem Resolution Sure

Solution  2153585.1 :   T10000B - SLS6625E REPORTED WRITE DATA CHK - FSC 3961, 3965  


Related Items
  • Sun StorageTek T10000B Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-12903955421>

Applies to:

Sun StorageTek T10000B Tape Drive - Version All Versions and later
Information in this document applies to any platform.

Symptoms

SHCC - V0160F96-MSG-.SLS6684I RTD V0160F96 ON VTSS VSM016 RETURNED ECAM ERROR CC=5 RC=109 - 22/06/16 05:59:13
.SLS6625E RTD V0160F96 REPORTED WRITE DATA CHK: 0A442025174A76203700396139653670351747000ADD1080CE0E5220648500FF

SHCC - TAPE-MSG-.SLS6605I INITIATING SWAP OF MVC 000365 FROM RTD V0160F96 - 22/06/16 06:46:00
SHCC - TAPE-MSG-.SLS6605I INITIATING SWAP OF MVC 000510 FROM RTD V0160F96 - 22/06/16 06:39:59
SHCC - TAPE-MSG-.SLS6605I INITIATING SWAP OF MVC 000519 FROM RTD V0160F96 - 22/06/16 06:28:54
SHCC - TAPE-MSG-.SLS6605I INITIATING SWAP OF MVC 000503 FROM RTD V0160F96 - 22/06/16 06:12:24
SHCC - TAPE-MSG-.SLS6605I INITIATING SWAP OF MVC 000450 FROM RTD V0160F96 - 22/06/16 06:06:46
SGCA - TAPE-MSG-.SLS6605I INITIATING SWAP OF MVC 000307 FROM RTD V1160F96 - 22/06/16 04:03:58
SGCA - TAPE-MSG-.SLS6605I INITIATING SWAP OF MVC 000351 FROM RTD V1160F96 - 22/06/16 03:53:54
SGCA - TAPE-MSG-.SLS6605I INITIATING SWAP OF MVC 000335 FROM RTD V1160F96 - 22/06/16 02:41:22
SHCC - TAPE-MSG-.SLS6605I INITIATING SWAP OF MVC 000450 FROM RTD V0160F96 - 22/06/16 00:21:42

The tape drive 0F96 is getting several FSC 3961 and 3965 to several different cartridges on every mount.

Cause

FSC Dictionary Description:
MODEL = T10000B
FSC = 3961
(FSC Match Found in Rev. 1.52)

FSC: 3961 RO_FSC_PW_LIMIT_ERROR_DUE_TO_WITH_VR2_DATA

MIM Code: NONE

FRU: HARDWARE CONF: 100%

Summary: |WRITE - WS MEDIA| RATE ERROR | *** |

Field Text:
An error occurred trying to write on tape using progressive write.

 

FSC Dictionary Description:
MODEL = T10000B
FSC = 3965
(FSC Match Found in Rev. 1.52)

FSC: 3965 RO_FSC_WRT_DISCONTINUITY_ERROR

MIM Code: NONE

FRU: MEDIA CONF: 50%

FRU: HARDWARE CONF: 50%

Summary: |OLD DATA NOT |OVERWRITTEN ON |WRITE |

Field Text:
The drive was not able to successfully overwrite old data when ramping up to write.

Solution

 Report the problem to Oracle Support for a determination of whether the drive should be replaced.
 


Attachments
This solution has no attachment