Solution Type Problem Resolution Sure Solution 2152273.1 : SL500 - Robot Down - FSC 5066
In this Document
Created from <SR 3-12882864861> Applies to:Sun StorageTek SL500 Modular Library System - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. SymptomsSL500 robot is DOWN Robot is not initializing Service Required / Service Robot LEDs are on. Time : 2016-06-15T16:44:49.988 Time : 2016-06-17T16:47:32.057 Time : 2016-06-17T16:47:32.150 Time : 2016-06-17T16:47:32.537 CauseRobot assembly could be faulty. Logs have shown a 5066 error as a result of an over current on one of the motors during robotic motion. The most likely cause of an over current condition on a motor is that an obstruction was encountered during that motion. SolutionThe most likely cause of an over current condition on a motor is that an obstruction was encountered during that motion. The FE should check for obstructions that may have caused that motion to stop before it should have. If no obstructions are found then a robot assembly needs to be replaced. Attachments This solution has no attachment |
||||||||||||||||
|