Solution Type Problem Resolution Sure Solution 2152017.1 : ES2-64 Unable to upgrade firmware due to Error:Maximum File Size Exceeded
In this Document
Created from <SR 3-12884759201> Applies to:Oracle Ethernet Switch ES2-64 - Version All Versions to All Versions [Release All Releases]Oracle Ethernet Switch ES2-72 - Version All Versions to All Versions [Release All Releases] Information in this document applies to any platform. SymptomsWhen upgrading SysFW of an ES2 switch, the following error is displayed: -> load -source ftp://username:password@x.x.x.x/ES2-72_64_SEFOS_2.0.0.7.pkg Error: Maximum file size exceeded Firmware image update failed. CauseOn Ethernet ES2 switches, there are two ILOM shells that differ by their prompts: -> prompt is reserved for SP ES2-> prompt is reserved for HOST
In the patch .zip archive, there are two firmware images. ES2-72_64_SEFOS_2.0.0.7.pkg ~120Mb ES2-72_64_SP_3.2.5.60_r109079.pkg ~13Mb When trying to load wrong firmware image, an error message is displayed. In doc E60180.pdf page 16, step 5, the load-source command is proceeded with -> prompt instead of ES2->prompt which may lead to issue described in this doc. SolutionThe HOST (SEFOS) must be upgraded before upgrading the Service Processor (SP).
To upgrade sefos:
Upgrade procedure is described in document Oracle Switch ES2-72 and Oracle Switch ES2-64 Product Notes available here: https://docs.oracle.com/cd/E60179_01/pdf/E60180.pdf Attachments This solution has no attachment |
||||||||||||||||
|