Solution Type  Problem Resolution Sure

Solution  2151575.1 :   Loading Of Session Border Controller Configuration To Communications Session Element Manager Fails with: is not a valid value of union type 'RealmNameOrStar'  


Related Items
  • Acme Packet 4500
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Session Delivery Network>SN-SND: Acme Service Provider
  •  




In this Document
Symptoms
Cause
Solution
  


Created from <SR 3-12688738641>

Applies to:

Acme Packet 4500 - Version S-Cx6.0.x to S-Cz7.3.0 [Release S-Cx6.0 to S-Cz7.0]
Information in this document applies to any platform.

Symptoms

Loading of Session Border Controller (SBC) configuration to the Communications Session Element Manager (formerly Net Net Central) fails with the error:

<RealmName> is not a valid value of union type 'RealmNameOrStar'

WHERE <RealmName> is a Realm Name in the configuration e,g

 

2016-05-13 15:44:43,782 ERROR [com.acmepacket.ems.server.services.config.ConfigMgrImpl] - Method: [getDevice] Thread: [RMI TCP Connection(46998)-10.179.72.24:268064] Msg:[encountered
validation errors.
validationErrors=
[ValidationError:]
path=config/localPolicy/sourceRealm
objectId=null
lineNumber=10561
columnNumber=40
instanceName=null
errorMessage=cvc-datatype-valid.1.2.3: 'access_VoIP_poslovni_Realm' is not a valid value of union type 'RealmNameOrStar'.
operation=null
invalidRefs=

 

 

 

Cause

This is a known issue with mapping the Communications Session Element Manager schema in newer versions of the SCX release.
In newer releases, with a new SBC configuration, it is not allow to write names with more than 24 characters.

More details can be found in the SCX 6.3 ACLI Reference guide (http://docs.oracle.com/cd/E50369_01/doc/sbc_scx630_aclireference.pdf):

 

Name Format Name entries must start with either an underscore symbol (_) or an alphabetical character from A through Z (A-Za-z).
After the first character, the field entry can contain any combination of alphabetical or numerical characters (0-9A-Za-z), as well
as the period (.), the dash (-), and the underscore (_) (e.g., acmepacket_configuration). The total entry can be from 1 to 24
characters in length.


 

Solution


Change the realm names so that it follows the correct criteria as outlined in the Cause
 

 

 

 

 