![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2150142.1 : Oracle ZFS Storage Appliance: How To Resolve - An unrecoverable problem was detected for a PCIEX device, which has resulted in that device running in a degraded state
In this Document
Applies to:Oracle ZFS Storage ZS3-2 - Version All Versions to All Versions [Release All Releases]Exalogic Elastic Cloud X4-2 Eighth Rack - Version X5 to X5 [Release X5] Sun ZFS Storage 7420 - Version All Versions to All Versions [Release All Releases] Sun ZFS Storage 7320 - Version All Versions to All Versions [Release All Releases] Sun ZFS Storage 7120 - Version All Versions to All Versions [Release All Releases] 7000 Appliance OS (Fishworks) SymptomsFMA generated this error message: PCIEX-8000-ND
An unrecoverable problem was detected for a PCIEX device, which has resulted in that device running in a degraded state.
CauseAn event was reported on the PCIe chip.
SolutionMark the fault as repaired and there should be no further issue.
BUI: Maintenance ->Problems -> Click on Problem -> Click 'Marked Repaired'
CLI: maintenance problems select <problem-id> markrepaired
References<NOTE:1019887.1> - Sun Storage 7000 Unified Storage System: How to Collect a Support Bundle using the BUI or CLI<NOTE:1020199.1> - How to Upload Support Files to Oracle Such as Explorer and Crash Dumps Attachments This solution has no attachment |
||||||||||||||||||
|