Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2149092.1
Update Date:2017-10-11
Keywords:

Solution Type  Problem Resolution Sure

Solution  2149092.1 :   SPARC M7 Series Servers : Host FW not updated after a SysFW update  


Related Items
  • SPARC M7-8
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>Enterprise>SN-SPARC: M7
  •  




In this Document
Symptoms
Cause
Solution
References


Applies to:

SPARC M7-8 - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

After a SysFW update, when using 'stop|start /SYS' or 'stop|start /System' or restarting the hosts too quickly, one or more hosts FW may not be updated during the hosts restart.

Cause

After a SySFW update, the host FW should be updated when the hosts are off or when restarting the hosts.

When using 'stop|start /SYS' or 'stop|start /System' or when restarting the hosts too quickly, one or more hosts FW may not be updated.

Even if bug 23251940 (fpga-uc / TPM Hardware error reported during SysFW update on M7) is fixed in SysFW 9.7.1.b, the system is still vulnerable to 23323122 (POD/PDM: Host firmware deployment at 'start /HOST' is broken).

 

Solution

To avoid this scenario

  • avoid using 'start /SYS' or 'start /System',
    • start the hosts individually 'start /HOSTx' or 'start /Servers/PDomains/PDomain_x/HOST'
  • before starting a host, user must make sure that the Host FW has been updated to the target version (show -t /Servers/PDomains/PDomain_x/SYSTEM/Firmware/Other_Firmware/ version)

Ex for host0 running Host FW from 9.7.1.b

-> show -t /Servers/PDomains/PDomain_0/SYSTEM/Firmware/Other_Firmware/ version
Target | Property | Value
----------------------------------------+-----------------------------------------------+--------------------------------------------------------------------
/Servers/PDomains/PDomain_0/SYSTEM/ | version | 3.2.6.2.b
Firmware/Other_Firmware/Firmware_0 | |
/Servers/PDomains/PDomain_0/SYSTEM/ | version | POST 5.5.1 2016/04/25 07:19
Firmware/Other_Firmware/Firmware_1 | |
/Servers/PDomains/PDomain_0/SYSTEM/ | version | OpenBoot 4.40.1 2016/04/25 06:45
Firmware/Other_Firmware/Firmware_2 | |
/Servers/PDomains/PDomain_0/SYSTEM/ | version | Hypervisor 1.17.1 2016/04/25 07:12

AND no Host FW update operation is in progress

-> show /Servers/PDomains/PDomain_0/HOST operation_in_progress

/Servers/PDomains/PDomain_0/HOST
Properties:
operation_in_progress = none

 

Information about SysFW and HostFW is available from SPARC M7 Series Servers : Firmware Image Software Version Matrix Information (Doc ID 1967048.1)

If the HostFW has not been updated after starting a host, there is no need to re-apply the SysFW image but the host must stopped and started again to apply the latest image.


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.