Solution Type  Problem Resolution Sure

Solution  2148385.1 :   T10000A - HW Errors Mounting Different Tapes During Backup Job, FSC 6101  


Related Items
  • Sun StorageTek T10000 Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
  •  




In this Document
Symptoms
Changes
Cause
Solution
 Applies to:


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential for Service Personnel
Created from <SR 3-12840805619>

Applies to:

Sun StorageTek T10000 Tape Drive - Version All Versions and later
Information in this document applies to any platform.
T10000A Version: 1.52.103-5.30

Symptoms

Event logs do not show any perm errors.
Drive dump reports FSC 6101 from the following tapes:

PR2234 (20)
PR2250 (9)
PR2238 (9)
PR2233 (2)
PR2241 (9)

Changes

 

Cause

FSC Dictionary Description:
MODEL = T10000A
FSC = 6101
(FSC Match Found in Rev. 1.52)

FSC: 6101 DC_FSC_ECPT_DCPT_TAG_CORRUPTED

MIM Code: DEGRADED

FRU: HARDWARE CONF: 100%

Summary: |*** | *** | *** |

Field Text:
The record read from the tape could not be decrypted.

Solution

Replaced drive.