Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2148348.1
Update Date:2016-06-13
Keywords:

Solution Type  Problem Resolution Sure

Solution  2148348.1 :   WARNING: fctl: ULP FCSM version mismatch; please upgrade FCSM  


Related Items
  • Sun Storage FC HBA
  •  
  • Solaris Operating System
  •  
  • Sun Fire V440 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>HBA>SN-DK: FC HBA
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-12840251401>

Applies to:

Sun Fire V440 Server - Version All Versions and later
Sun Storage FC HBA - Version All Versions and later
Solaris SPARC Operating System - Version 9 GA to 9 9/05 HW U9 [Release 9.0]
Information in this document applies to any platform.

Symptoms

The following warnings are observed in /var/adm/messages:

Jun 7 02:55:30 xxx fcsm: [ID 517869 kern.warning] WARNING: fcsm: _init: Please upgrade this module. Current version 0x2 is not the most recent version
Jun 7 02:55:35 xxx fctl: [ID 352867 kern.warning] WARNING: fctl: ULP FCSM version mismatch; please upgrade FCSM

 

Cause

The currently installed fcsm patch is not the latest.

The latest is 114476-10

 

Solution

Install patch 114476-10

Reboot the system


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.