Solution Type  Problem Resolution Sure

Solution  2147173.1 :   Diameter Signaling Router (DSR) - The Per-Connection Control is Not Working For Users Belonging to Groups With Only “Diameter Maintenance Permissions” Activated  


Related Items
  • Oracle Communications Diameter Signaling Router (DSR)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec DSR
  •  




In this Document
Symptoms
Cause
Solution
References


Created from <SR 3-12724481291>

Applies to:

Oracle Communications Diameter Signaling Router (DSR) - Version DSR 5.0 and later
Information in this document applies to any platform.

Symptoms

When configuring new user belonging to a group having all “Diameter Maintenance Permissions” activated, it was noticed that this new user doesn't have the possibility to enable/disable the connections one by one under the "SOAM GUI -> Main Menu -> Diameter -> Maintenance -> Connections" menu. The per connection enable/disable buttons of the "SOAM GUI -> Main Menu -> Diameter -> Maintenance -> Connections" menu are greyed.

Cause

Investigations showed that the per connection permission control goes along with the so called CONNECTION_PERM (Diameter Configuration Permissions -> Connection -> View) while the disable/enable all permission goes along with so called CONNECTIONSTATUS_PERM (Diameter Maintenance Permissions -> Connection -> View).

A Bug has been created in order to include the per connection permission control into the "Diameter Maintenance Permissions" set.  

Solution

As workaround, activate the view permission for the following menu "Diameter Configuration Permissions -> Connections" on the concerned group permissions level.

Please note that activating the "Diameter Configuration Permissions -> Connections:view" permissions will give access to the "SOAM GUI -> Main Menu -> Diameter -> Configuration -> Connection" menu.

 

References

<BUG:23522925> - DSR PER CONNECTION MAINTENANCE PERMISSION DEPENDS ON CONFIG PERMISSION.

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.