Asset ID: |
1-72-2146235.1 |
Update Date: | 2017-09-05 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
2146235.1
:
IBM LTO5 - Amber LED Flashing With Letter A - Problem Excessive Mount of Cleaning Cartridges
Related Items |
- Sun StorageTek SL500 Modular Library System
- IBM LTO5 Tape Drive
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL500 Library
|
In this Document
Created from <SR 3-12712637771>
Applies to:
IBM LTO5 Tape Drive - Version All Versions and later
Sun StorageTek SL500 Modular Library System - Version All Versions and later
Information in this document applies to any platform.
Symptoms
LED amber in flashing;
In drive Display is showing the letter A;
High consume of clean cartridges.
In Eventlog has 25 mounts of clean cartridges in Drive 0,2,2,9:
Time : 2016-05-16T02:08:55.607
Device Address : 0.0.0.0.0
User : unknown
Requester : default
Activity : 3000
Request Id : (null)
Level : error
Result Code : 3335
Text : , "(request id = HOST/0x1025da68) (request id = HOST/0x0x1025da68) IfmMove::prepareForMove():AFTER dc.issueCommand():userState==6:Drive source (LMRC) 0,2,2,9 drive busy cleaning."
Time : 2016-05-18T16:18:39.967
Device Address : 0.0.0.0.0
User : unknown
Requester : default
Activity : 3000
Request Id : (null)
Level : error
Result Code : 3335
Text : , "(request id = HOST/0x1025da68) (request id = HOST/0x0x1025da68) IfmMove::prepareForMove():AFTER dc.issueCommand():userState==6:Drive source (LMRC) 0,2,2,9 drive busy cleaning."
The amber LED in flashing is Service Request..
Cause
In Display the letter A is Tape Drive Hardware problem..
SCD error codes for the LTO tape drivesSCD Code Description
0 No Error. Ran successfully.
1 Cooling problem.
2 5V dc power problem. Tape drive detected that the Drive Power Supply is approaching the specified voltage limit (drive is still operating) or is outside the specified voltage range (drive is not operating).
3 Tape drive determined that a microcode error occurred.
4 Microcode or tape drive problem. Tape drive determined that a microcode or tape drive hardware failure occurred.
5 Tape drive problem. Tape drive determined that a hardware failure occurred.
6 Tape drive or media error. Tape drive determined that an error occurred, but it cannot isolate the error due to faulty hardware or to the tape cartridge.
7 Media error.
8 Tape drive, SCSI bus or fibre channel error.
9 Tape drive or RS-422 error.
A Tape drive hardware problem. <<<<<========
B No error or message is assigned.
C Tape drive needs to be cleaned.
D No error or message is assigned.
= The Unload button on the drive was pushed in and did not release.
Solution
Replaced the tape drive according action plan. Solved the issue.
How to Remove / Replace a Tape Drive in SL500 Library:ATR:1353561.1:2 (Doc ID 1353561.1)
Attachments
This solution has no attachment