![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Problem Resolution Sure Solution 2145900.1 : T10000A - (FSC 495E) - TSM get Messages ANR8355E.
In this Document
Oracle Confidential PARTNER - Available to partners (SUN). Applies to:Sun StorageTek T10000A Tape Drive - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. SymptomsTwo Drives T10000A is getting check 4056 with several cartridges different: FSC: 36A3 CauseBy customer messages errors we can see the error code 495E. ===>>> ANR8944E SENSE=70.00.04.00.00.00.00.12.00.00.00.00.15.01.00.00.00.00.49.5E.35.1A.00.00.10.02., Description=Drive failure) FSC: 495E SI_FSC_MOT_CMD_BUT_REC_TAPE_TENSION MIM Code: DEGRADED FRU: MEDIA CONF: 80% FRU: HARDWARE CONF: 15% FRU: MICROCODE CONF: 5% Summary: |TAPE NOT UNDER |TENSION |INVALID STATE. | Field Text: The servo interface task received a command that requires tape tension. Unfortunately we are in a state trying to recover the tape tension, so the command could not be performed. Issue an unload to get the tape out of the drive and retry with another tape. * By evenlog of the drive and it was showing FSC 36A3. FSC: 36A3 RO_FSC_MAN_UNLOAD_MIR_WRT_ERROR MIM Code: NONE FRU: MEDIA CONF: 95% FRU: HARDWARE CONF: 5% Summary: |WRITE MIR ERROR | *** | *** | Field Text: The MIR could not be written without error. Tape may be marginal. Engineering Text: During a manual unload, the MIR could not be written without error. Thus the tape is marginal at best and should be replaced. SolutionThe Drive was replaced. Attachments This solution has no attachment |
||||||||||||||||
|