Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2145900.1
Update Date:2017-08-16
Keywords:

Solution Type  Problem Resolution Sure

Solution  2145900.1 :   T10000A - (FSC 495E) - TSM get Messages ANR8355E.  


Related Items
  • Sun StorageTek T10000A Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
  •  




In this Document
Symptoms
Cause
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Need Internal action
Created from <SR 3-12780128521>

Applies to:

Sun StorageTek T10000A Tape Drive - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

Two Drives T10000A is getting check 4056 with several cartridges different:

2016-05-30-08.10,ANR8355E I/O error reading label for volume SO0155 in drive SL8500_SEC01_F241 (/dev/mt94). (SESSION: 158998)
2016-05-30-08.10,"ANR8944E Hardware or media error on drive SL8500_SEC01_F241 (/dev/mt94) with volume SO0155(OP=REW, Error Number= 5, CC=305, KEY=04, ASC=15, ASCQ=01, SENSE=70.00.04.00.00.00.00.12.00.00.00.00.15.01.00.00.00.00.49.5E.35.1A.00.00.10.02., Description=Drive failure). Refer to the IBM Tivoli Storage Manager documentation on I/O error code descriptions. (SESSION: 158928)"

2016-05-27-23.15,ANR8355E I/O error reading label for volume SO0013 in drive SL8500_SEC01_F242 (/dev/mt14). (SESSION: 153582)
2016-05-27-23.15,"ANR8944E Hardware or media error on drive SL8500_SEC01_F242 (/dev/mt14) with volume SO0013(OP=REW, Error Number= 5, CC=305, KEY=04, ASC=15, ASCQ=01, SENSE=70.00.04.00.00.00.00.12.00.00.00.00.15.01.00.00.00.00.49.5E.35.1A.00.00.14.02., Description=Drive failure). Refer to the IBM Tivoli Storage Manager documentation on I/O error code descriptions. (SESSION: 153374)"

FSC: 495E

FSC: 36A3

Cause

By customer messages errors we can see the error code 495E.

===>>> ANR8944E

SENSE=70.00.04.00.00.00.00.12.00.00.00.00.15.01.00.00.00.00.49.5E.35.1A.00.00.10.02., Description=Drive failure)

FSC: 495E SI_FSC_MOT_CMD_BUT_REC_TAPE_TENSION
MIM Code: DEGRADED
FRU: MEDIA CONF: 80%
FRU: HARDWARE CONF: 15%
FRU: MICROCODE CONF: 5%
Summary: |TAPE NOT UNDER |TENSION |INVALID STATE. |
Field Text:
The servo interface task received a command that requires tape tension. Unfortunately we are in a state trying to recover the tape tension, so the command could not be performed. Issue an unload to get the tape out of the drive and retry with another tape. *
 
By evenlog of the drive and it was showing FSC 36A3.

FSC: 36A3 RO_FSC_MAN_UNLOAD_MIR_WRT_ERROR
MIM Code: NONE
FRU: MEDIA CONF: 95%
FRU: HARDWARE CONF: 5%
Summary: |WRITE MIR ERROR | *** | *** |
Field Text:
The MIR could not be written without error. Tape may be marginal.
Engineering Text:
During a manual unload, the MIR could not be written without error. Thus the tape is marginal at best and should be replaced.

 

Solution

The Drive was replaced.
 


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.