Solution Type  Problem Resolution Sure

Solution  2145429.1 :   SL150 - Tape Library In Inoperative State, Error 0.0.0.0.0 9009 "PS FAULT (Module Power Supply AC OK Line Indicates a Failure)  


Related Items
  • StorageTek SL150 Modular Tape Library
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL150 Library
  •  




In this Document
Symptoms
Cause
Solution
 Applies to:


Created from <SR 3-12757718012>

Applies to:

StorageTek SL150 Modular Tape Library - Version All Versions and later
Information in this document applies to any platform.

Symptoms

Tape library in Inoperative State

Found several P/S failures:

Current Power Supplies

ID Present Status
1 true Inoperative
2 true Inoperative
3 true Operative
4 true Operative
5 true Inoperative
6 true Inoperative

2016-05-22T09:49:44.745 error 0.0.0.0.0 9009 "PS FAULT (Module power supply AC OK line indicates a failure): module:1 position:2, statusWord:0xFFFF, firmwareVersion:0x525"
2016-05-22T09:55:11.487 error 0.0.0.0.0 9009 "PS FAULT (Module power supply AC OK line indicates a failure): module:1 position:2, statusWord:0xFFFF, firmwareVersion:0x525"
2016-05-22T09:58:22.892 error 0.0.0.0.0 9009 "PS FAULT (Module power supply AC OK line indicates a failure): module:1 position:2, statusWord:0xFFFF, firmwareVersion:0x525"
2016-05-22T10:13:09.129 error 0.0.0.0.0 9009 "PS FAULT (Module power supply AC OK line indicates a failure): module:1 position:2, statusWord:0xFFFF, firmwareVersion:0x525"
2016-05-22T10:15:07.254 error 0.0.0.0.0 9009 "PS FAULT (Module power supply AC OK line indicates a failure): module:1 position:2, statusWord:0xFFFF, firmwareVersion:0x525"
2016-05-22T10:16:56.155 error 0.0.0.0.0 9009 "PS FAULT (Module power supply AC OK line indicates a failure): module:1 position:2, statusWord:0xFFFF, firmwareVersion:0x525"
2016-05-22T10:19:58.867 error 0.0.0.0.0 9009 "PS FAULT (Module power supply AC OK line indicates a failure): module:1 position:2, statusWord:0xFFFF, firmwareVersion:0x525"
2016-05-22T10:22:06.039 error 0.0.0.0.0 9009 "PS FAULT (Module power supply AC OK line indicates a failure): module:1 position:2, statusWord:0xFFFF, firmwareVersion:0x525"

2016-05-22T09:50:30.981 error 0.0.0.0.0 9009 "PS FAULT (Module power supply AC OK line indicates a failure): module:1 position:1, statusWord:0xFFFF, firmwareVersion:0x525"
2016-05-22T09:56:35.914 error 0.0.0.0.0 9009 "PS FAULT (Module power supply AC OK line indicates a failure): module:1 position:1, statusWord:0xFFFF, firmwareVersion:0x525"
2016-05-22T10:03:32.329 error 0.0.0.0.0 9009 "PS FAULT (Module power supply AC OK line indicates a failure): module:1 position:1, statusWord:0xFFFF, firmwareVersion:0x525"
2016-05-22T10:16:49.437 error 0.0.0.0.0 9009 "PS FAULT (Module power supply AC OK line indicates a failure): module:1 position:1, statusWord:0xFFFF, firmwareVersion:0x525"
2016-05-22T10:20:36.154 error 0.0.0.0.0 9009 "PS FAULT (Module power supply AC OK line indicates a failure): module:1 position:1, statusWord:0xFFFF, firmwareVersion:0x525"
2016-05-25T10:25:24.386 error 0.0.0.0.0 9009 "PS FAULT (Module power supply AC OK line indicates a failure): module:1 position:1, statusWord:0xFFFF, firmwareVersion:0x525"
2016-05-25T10:29:02.705 error 0.0.0.0.0 9009 "PS FAULT (Module power supply AC OK line indicates a failure): module:1 position:1, statusWord:0xFFFF, firmwareVersion:0x525"

2016-05-22T09:51:52.366 error 0.0.0.0.0 9009 "PS FAULT (Module power supply AC OK line indicates a failure): module:2 position:1, statusWord:0xFFFF, firmwareVersion:0x525"
2016-05-22T09:54:24.567 error 0.0.0.0.0 9009 "PS FAULT (Module power supply AC OK line indicates a failure): module:2 position:1, statusWord:0xFFFF, firmwareVersion:0x525"
2016-05-22T10:02:48.313 error 0.0.0.0.0 9009 "PS FAULT (Module power supply AC OK line indicates a failure): module:2 position:1, statusWord:0xFFFF, firmwareVersion:0x525"
2016-05-25T10:22:17.967 error 0.0.0.0.0 9009 "PS FAULT (Module power supply AC OK line indicates a failure): module:2 position:1, statusWord:0xFFFF, firmwareVersion:0x525"
2016-05-25T10:26:34.614 error 0.0.0.0.0 9009 "PS FAULT (Module power supply AC OK line indicates a failure): module:2 position:1, statusWord:0xFFFF, firmwareVersion:0x525"

2016-05-22T09:52:51.906 error 0.0.0.0.0 9009 "PS FAULT (Module power supply AC OK line indicates a failure): module:2 position:2, statusWord:0xFFFF, firmwareVersion:0x525"
2016-05-22T09:55:41.609 error 0.0.0.0.0 9009 "PS FAULT (Module power supply AC OK line indicates a failure): module:2 position:2, statusWord:0xFFFF, firmwareVersion:0x525"
2016-05-22T10:02:13.942 error 0.0.0.0.0 9009 "PS FAULT (Module power supply AC OK line indicates a failure): module:2 position:2, statusWord:0xFFFF, firmwareVersion:0x525"
2016-05-22T10:05:39.919 error 0.0.0.0.0 9009 "PS FAULT (Module power supply AC OK line indicates a failure): module:2 position:2, statusWord:0xFFFF, firmwareVersion:0x525"
2016-05-22T10:08:40.591 error 0.0.0.0.0 9009 "PS FAULT (Module power supply AC OK line indicates a failure): module:2 position:2, statusWord:0xFFFF, firmwareVersion:0x525"
2016-05-22T10:11:24.248 error 0.0.0.0.0 9009 "PS FAULT (Module power supply AC OK line indicates a failure): module:2 position:2, statusWord:0xFFFF, firmwareVersion:0x525"
2016-05-22T10:15:16.187 error 0.0.0.0.0 9009 "PS FAULT (Module power supply AC OK line indicates a failure): module:2 position:2, statusWord:0xFFFF, firmwareVersion:0x525"
2016-05-22T10:21:10.017 error 0.0.0.0.0 9009 "PS FAULT (Module power supply AC OK line indicates a failure): module:2 position:2, statusWord:0xFFFF, firmwareVersion:0x525"

Modules 1 and 3 has no power supply operational.

Cause

Having no power on Module 1 is the root cause the robot is not operative.

Solution

Replace the robotic module to resolve issue.