Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2145045.1
Update Date:2017-06-29
Keywords:

Solution Type  Problem Resolution Sure

Solution  2145045.1 :   IMT Bus is Fluctuating  


Related Items
  • Oracle Communications EAGLE (Hardware)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec Eagle 5
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-12754683181>

Applies to:

Oracle Communications EAGLE (Hardware) - Version EAGLE 3x.x and later
Information in this document applies to any platform.

Symptoms

The IMT bus is fluctuating and hence bouncing.

Cause

One card is introducing some noise on the IMT bus
 
 

Solution

Re-seating the card, which introduced the noise on the bus, stopped the bouncing
 


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback