Asset ID: |
1-72-2144997.1 |
Update Date: | 2017-08-16 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
2144997.1
:
IBM LTO2 - Tape Drives Are Not Operational FSC # 3E24 and FSC 3E0A
Related Items |
- Sun StorageTek L700 Tape Library
- IBM LTO2 Tape Drive
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK Legacy Drive and Library
|
In this Document
Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential for Service Personnel
Created from <SR 3-12703831980>
Applies to:
Sun StorageTek L700 Tape Library - Version All Versions and later
IBM LTO2 Tape Drive - Version All Versions and later
Information in this document applies to any platform.
Symptoms
Sun StorageTek L700/ Two IBM LTO2 Tape Drives in PL2 Library are not working.
------------- FSC # 3e0a (hex) --------------
SEVERITY : Warning
MECHANISM : DRIVE_03_00
OCCURRENCES : 17
LAST OCCURRENCE : 5/17/2016
: 15:53:57
:
SUMMARY : DRV Command Failed - TTI communication to drive failed.
TEXT : DRV Command Failed - TTI communication to drive failed.
&&3e0a
ERR_DRV_CMD_TTI_FAILURE,
DRV Command Failed - TTI communication to drive failed.
FRU: LOCATION: CONFIDENCE %:
DRIVE LIBRARY 90
LOGICAL ERROR S/W 10
SEVERITY - warn
------------- FSC # 3e14 (hex) --------------
SEVERITY : Informational
MECHANISM : DRIVE_03_00
OCCURRENCES : 4
LAST OCCURRENCE : 5/16/2016
: 21:47:59
:
SUMMARY : DRV Drive Connection State Transition - Drive not connected.
TEXT : DRV Drive Connection State Transition - Drive not connected.
&&3e14
ERR_DRV_CONN_STATE_NOT_CONNECTED,
DRV Drive Connection State Transition - Drive not connected.
FRU: LOCATION: CONFIDENCE %:
DRIVE LIBRARY 99
LOGICAL ERROR S/W 01
SEVERITY - inform
------------- FSC # 3e24 (hex) --------------
SEVERITY : Warning
MECHANISM : DRIVE_07_00
OCCURRENCES : 2
LAST OCCURRENCE : 5/16/2016
: 20:44:12
:
SUMMARY : DRV Wait for Rewind Failed - Loaded State reported during wait.
TEXT : DRV Wait for Rewind Failed - Loaded State reported during wait.
&&3e24
ERR_DRV_REWIND_WAIT_LOADED_STATE,
DRV Wait for Rewind Failed - Loaded State reported during wait.
FRU: LOCATION: CONFIDENCE %:
DRIVE LIBRARY 90
LOGICAL ERROR S/W 10
SEVERITY - warn
Cause
Possible Causes:
-- Drive mechanism could be faulty
-- Drive read/write head could be faulty
-- The load / unload mechanism won't come to its appropriate position, manual intervention is required to pull the load / unload mechanism to make the drive status to "empty"
Solution
-- FSE needs to inspect the drives physically.
-- Perform tape drives repair and diagnostics test.
-- Replace the part if necessary.
In this case parts replacement resolved the issues.
Attachments
This solution has no attachment