Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2144952.1
Update Date:2017-09-13
Keywords:

Solution Type  Problem Resolution Sure

Solution  2144952.1 :   SL8500 - LSM Error, Code87 no Format for Type_code87: Library Error, LSM Offline Maintenance  


Related Items
  • Sun StorageTek SL8500 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
  •  




In this Document
Symptoms
Cause
Solution
References


Created from <SR 3-12582145641>

Applies to:

Sun StorageTek SL8500 Modular Library System - Version All Versions and later
Information in this document applies to any platform.

The current ACSLS version is at 8.02.

The current solaris version details are as below.

Oracle Solaris 10 1/13 s10s_u11wos_24a SPARC
Copyright (c) 1983, 2013, Oracle and/or its affiliates. All rights reserved.
Assembled 17 January 2013

Version: FRS_8.07 (6.91.00)

Symptoms

SL8500: LSM error

No critical errors were showing in the log snapshot.Customer receiving the below error in their ACSLS logs.


code87 no format for type_code87:library error, lsm offline maintenance

 

Cause

Software issue.

Solution

Issue is resolved after firmware upgrade to 8.51.

Issue is fixed in ACSLS 8.4.
Upgrade the ACSLS to 8.4 for fixing this issue .
There is no patch addressing this issue for prior versions of ACSLS than 8.4.0

Solaris 11.2 is a minimum requirement for ACSLS 8.4.


 

References

<NOTE:1017409.1> - ACSLS - ACSLS fills event logs with "LSM is not ready" error messages
<BUG:15690888> - SUNBT7011286 CODE 87 NO FORMAT FOR TYPE_CODE 87: LIBRARY ERROR, LSM OFFLINE MAIN
<NOTE:1529585.1> - ACSLS - Unexpected resource type code 86 - STATUS_LIBRARY_FAILURE
<NOTE:1017145.1> - ACSLS - How to Enable Tracing of acslh Process
<NOTE:1013165.1> - ACSLS - How to Gather Diagnostic Logs and Information
<NOTE:1307534.1> - SL3000/SL8500 - How to Collect Log Snapshot From SL8500 or SL3000 Library

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.