Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2144036.1
Update Date:2017-07-03
Keywords:

Solution Type  Problem Resolution Sure

Solution  2144036.1 :   SL48 - Tape Library Robotic Error - Sled Position Not Found Error Code 0x9B  


Related Items
  • Sun StorageTek SL48 Tape Library
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: OEM Drive and Library
  •  




In this Document
Symptoms
Cause
Solution
References


Created from <SR 3-12723288334>

Applies to:

Sun StorageTek SL48 Tape Library - Version All Versions and later
Information in this document applies to any platform.

Symptoms

Robotic error : Sled position not found Error 0x9B

14.10.17 15:14:44.09 LIB/ERR<80 9B 2C 14 > HE: sled position not found
14.10.17 15:12:29.64 LIB/ERR<80 9B 2C 00 > HE: sled position not found
14.10.17 15:02:44.89 LIB/ERR<80 9B 2C 00 > HE: sled position not found
14.10.17 14:51:36.99 LIB/ERR<80 9B 2C 00 > HE: sled position not found
11.11.04 15:31:52.99 LIB/ERR<80 B3 00 00 > HE: robotic emergency stop
10.05.12 11:35:49.97 LIB/ERR<80 B3 71 32 > HE: robotic emergency stop
09.03.27 23:55:34.41 LIB/ERR<80 8D 14 00 > HE: sled blocked

Cause

Robot obstruction.

Solution

1. Update firmware to the latest revision. Firmware enhancements have been added which may prevent the condition that causes this error.(Library Firmware: H.70/3.20e and Library Patch : 128439-12)
2. Ensure that there is nothing stacked on top of the library since any weight on top of the product can bow the top cover down and interfere with the robotics. Ensure that the product is either mounted in a rack using its rack kit or mounted in the optional tabletop conversion cover with all of its feet sitting on a level surface. The product must be supported on its side edges for the robotics to move freely. Setting the product on a rack shelf or other flat surface without the tabletop conversion cover does not provide the necessary edge support.
3. Remove all magazines and drives to ensure that there are no obstructions in the library such as loose tapes on the inside of the library.
4. Run the wellness test.
 

References

<NOTE:1539632.1> - How To Download Tape Drive, Library Firmware and Installation Tools from My Oracle Support
<NOTE:1369772.1> - SL24/SL48 - How to Run Wellness / Diagnostic Test on Library
<NOTE:1372168.1> - How to Upgrade Firmware in SL48 Library:ATR:1372168.1:0