![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Problem Resolution Sure Solution 2142944.1 : Fujitsu M10-4/M10-4S: XSCF does not Identify M10 PCI Expansion Unit
In this Document
Applies to:Fujitsu M10 PCI Expansion Unit - Version All Versions and laterFujitsu M10-4 - Version All Versions and later Fujitsu M10-4S - Version All Versions and later Information in this document applies to any platform. SymptomsIn some cases the XSCF does not identify the installed PCI Expansion Unit ( PCIBOX ) when the PPAR is powered on, resulting in the logical domain not booting. XSCF> ioxadm list
PCIBOX Link PCIBOX#2333 BB#00-PCI#03 PCIBOX#3555 BB#00-PCI#05 XSCF> As the result of this, when the pciboxdio command is enabled on the logical domain configuration, the logical domain cannot be booted because of the factory-default configuration. XSCF> showpciboxdio -a
PCI slot Direct I/O via PCIBOX BB#00 0 enabled 1 disabled 2 disabled 3 disabled 4 disabled 5 disabled 6 disabled 7 disabled 8 disabled 9 disabled 10 disabled Example 2: The logical domain configuration can be confirmed as follows. E.g. in the case that the logical domain configuration of PPAR ID 0 is the factory-default. XSCF> showdomainconfig -p 0
PPAR-ID :0 Booting config (Current) :factory-default ^^^^^^^^^ ^^^^^^^^^^^^^^^ (Next) :factory-default Because XSCF can not identify the installed PCIBOX, ioxadm commands cannot be executed for the missing PCIBOX.
CauseThis problem is caused by XSCF firmware bug introduced in XCP2250.
SolutionWorkaround: This problem will be fixed in the next XCP. Please apply the fix once it has been released. Attachments This solution has no attachment |
||||||||||||||||
|