![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Problem Resolution Sure Solution 2142934.1 : Fujitsu M10-4: M10 PCI Expansion Unit Firmware Update Failure
In this Document
Applies to:Fujitsu M10-4 - Version All Versions and laterFujitsu M10 PCI Expansion Unit - Version All Versions and later Information in this document applies to any platform. SymptomsUpdating of the Fujitsu M10 PCI Expansion Unit firmware may fail with the following message: XSCF> ioxadm -c update PCIBOX#8002 -s 1200
Firmware update is started. (version=1200) Operation was not successful. XSCF> There is also a secondary issue where a M10 PCI Expansion Unit installed in PCI-slot#9 will take more than 2 hours until ioxadm completes with the above error. CauseThis issue is caused by a bug in XCP2250.
SolutionThis problem will be fixed in the next XCP release. Please apply the fix once it has been released. Attachments This solution has no attachment |
||||||||||||||||
|